Post Offer Free
Beijing Zhongzhiguochuang Automation Equipment Co.,ltd  

Gold Index: 3123

You are here: home  > Industry Wall mounted ultrasonic Flow Meter with English Menu TF -2000S

Industry Wall mounted ultrasonic Flow Meter with English Menu TF -2000S 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail


 Wall mounted type ultrasonic Flow Meter with English Menu<span style="font-family:arial,helvetic

 Wall mounted type ultrasonic Flow Meter with English Menu
Quick Detail:
 
1. Accuracy: Better than 1%
2. Repeatability: 0.2%
3. Certifiacte: EMC and LVD
 
 
Description:
 
The TF -2000S ultrasonic flow meter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation. The TF -2000S transit - time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V- method where the sound transverses the pipe twice, or W- method where the sound transverses the pipe four times, or in Z-method where the transducers are mounted on opposite sides of the pipe and the sound crosses the pipe once. This selection of the mounting method depends on pipe and liquid characteristics. The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers and measuring the transit time that it takes for sound to travel between the two transducers. The difference in the transit time measured is directly and exactly related to the velocity of the liquid in the pipe, show as follows:
 
 
 
Wall Mounted Ultrasonic Flowmeter
 
 
Where
Where hereθis the include angle to the flow direction, M is the travel times of the ultrasonic beam, D is the pipe diameter Tup is the time for the beam from upstream transducer to the downstream one Tdown is the time for the beam from downstream transducer to the upstream one
Δ T=Tup – Tdown
 
 
 
III Features
 
1.Linearity: 0.5%, Repeatability: 0.2%, Accuracy: ± 1%
2.Easy to operate.
3.Several type transducer s for selection, measuring pipe size is from DN15mm to DN6000mm
4.Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
5.Powerful Recording Function, record the totalizer data of the last 64 days/64monthes/5 years.
 
 
Applications:
 
    It can be used in water, heating, water conservancy, metallurgy, chemical industry, machinery, energy and other industries. Also can be used as production monitoring, flow quantity checking, temporary detection, traffic inspection, water balance test, thermal net balance debugging, energy monitoring, detecting when flow is necessary tool instrument.
 
 
Specifications:
 

FeaturesDescription
High Accuracy measuringLinearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1%
Wide measuring rangeSeveral types transducer for selection, measuring pipe size from DN15mm to DN6000mm
Chinese & English menuDifferent version UFM can support Chinese or English display, easy to operate.
High ReliabilityAdopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
Strong Anti-interferenceDual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc.
Powerful Recording Function

Automatically record the following data:
1. The totalizer data of the last 512 days/128 months/10 years
2. The time and corresponding flow meter of the last 64 times of power on and off events
3. The working status of the last 32 days

 
 

Optional TransducerModelMeasuring RangeLiquid TemperatureAccuracy

 
 
 
Clamp-on Transducer

TS-1(Small Size)TF-2000SNB1DN15-100mm-30°C~90°C±1%
TM-1(Medium Size)TF-2000SNB2DN50-1000mm
TL-1(Large Size)TF-2000SNB3DN300-6000mm

 
High-temperature
Clamp-on Transducer

THS-1(Small Size)TF-2000SNB4DN15-100mm-30°C~160°C
THM-1(Medium Size)TF-2000SNB5DN300-1000mm

 
 
Insertion Transducer

TC-1(Standard)TF-2000SNC1DN80-6000mm-40°C~160°C
TLC-2(Lengthen)TF-2000SNC2

 
Prover section

Prover sectionTF-2000SNGDN15-1000mm-40°C~160°C±0.5%
Power SupplyDC8-36V or AC85-264V
Input3 channel 4-20mA analog input
OutputIsolation RS-485 output, 2 channel isolation OCT output: 1 channel isolation 4-20mA output (two-wire system)
Communication ProtocolsCompatible with METER-BUS, MODBUS, Fuji extended protocol and general water meter protocol.

 
 
Competitive Advantage:
 
 
1 Handle Ultrosonic Flowmeter 2 Repeatability 0.2%
3 Accuracy better than 1%
4 Response Time 0-999 second
5 Lin:0.5%

 
 
If you have any question PLease contact us. SKYPE :susan86861 .
 
 

bigPhoto
 Mr. Shouyan Huo

Tel: 86-10-52900365
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Beijing Zhongzhiguochuang Automation Equipment Co.,ltd [China (Mainland)]


Business Type:Manufacturer
City: Beijing
Province/State: Beijing
Country/Region: China (Mainland)

You May Like:

Product (63)